ECONET

COMPACT 3

check box Hoog contrast TFT-scherm met SpO2, NIBP, Temperatuur

check box Operated through external power supply or vehicle electrical system

check box Li-ion battery operation for up to 5 hours

check box Trend memory for over 128 hours

check box Alarm memory for 20 alarms with 10 sec. each

check box Integrated connector sockets for Network and USB

check box Incl. SpO2 sensor blood pressure cuff for adults

check box Weighs only 1kg

check box Accessories included

check box Display: 4,3″ Colour TFT-Monitor

check box Dimension: 187 (W) x 131 (H) x 60 (D)mm, ca. 1,1 kg

check box Indicators

Up to 2 waves;

Categorized alarms (4 priority levels);

Heart rate, SpO2 pitchtone;

Battery status;

External power LED

check box Interfaces

DC input: 15V, 2A;

LAN digital output for transfering data;

Nurse call system connection;

DC output: 5V, 1A max.;

USB Pport;

VGA output (optional)

check box Battery

Type: rechargeable Li-ion battery

Operation time: up to 5 hours fully charged

check box Tabular trend

Memory storage: 120 hours

Intervals: 1, 5, 15, 30, 60 min.

Format: tabular form for all parameters

check box Graphical trend 

Display duration: 30, 60, 90, 180, 360, 720 min.

check box Saturation range: 0% – 100%

check box Heart rate: 0 – 254 bpm

check box SpO2 accuracy

70% – 100% = approximately 2%

0% – 69% = unspecified

check box Heart rate accuracy: approximately 2 bp

check box Pitchtone: yes

check box Method: Oscillometric

check box Operation Mode

Manual: single measurement

Within intervals: 1, 2, 3, 4, 5, 10, 15, 20, 240, 480 min

check box Measurement range

0 – 300 mmHg

Systole: 60 – 250 mmHg

Mean: 40 – 235 mmHg

Diastole: 30 – 220 mmHg

check box Cuff pressure: adjustable

check box Measurement range: 15°C – 45°C (59°F – 113°F)

check box Accuracy

25°C – 45°C = 0.1°C

15°C – 24°C = 0.2°C

check box Compatibility: YSI Series 400

check box Module: Respironics Mainstream/Sidestream

check box Measurement range: 0 – 150 mmHg

check box Accuracy

0 – 40 mmHg = 2 %

41 – 70 mmHg = 5%

71 – 100 mmHg = 8%

101 – 150 mmHg = 10%

check box Respiration rate: 2 – 150 breath per min.

check box Respiration accuracy: 1 breath per min.

check box Standard accessories

NIBP extension tube

NIBP cuff (25-35cm)

SpO2 extension cable

SpO2 sensor (adult)

DC adapter, 15V 2A

check box Optional accessories

Temperature probe: skin, rectal/oral for adults

NIBP cuff for children and neonates

ECONET

COMPACT 5

check box 7″ wide TFT color monitor (800×480 pixels)

check box 2ch. ECG, SpO2, NIBP, Respiration, Temperature

check box 120 hours trends saving time

check box Networkable with PC (LAN, RS-232, HL7 and optional WLAN)

check box ST & PVC analysis

check box Built-in rechargeable Li-ion battery and printer

check box Display: 7″ Wide colour TFT-Monitor (800×480)

check box Dimension: 238 (W) x 250 (H) x 155 (D)mm, ca. 3,1 kg

check box Indicators

Up to 4 waves;

Categorized alarms (3 priority levels);

Heart rate, SpO2 pitchtone;

Battery status;

External power LED

check box Interfaces

DC input connector: 18VDC, 2.5A;

Defib. Sync. Output

  • Signal level: 0 – 5 V pulse
  • Pulse width: 100 approx. 10 ms

LAN digital output for transfering data;

Nurse call system connection;

DC output: 3.3 VDC, 1A max.;

check box Battery

Type: Li-ion battery

Battery status indicator

Operation time: up to 3 hours fully charged

check box Thermal Printer (standard)

Speeds: 25, 50 mm/sec

Paper width: 57 mm

check box Tabular trend

Memory storage: 120 hours

Intervals: 1, 5, 15, 30, 60 min.

Format: tabular form for all parameters

check box Graphical trend 

Display duration: 30, 60, 90 minutes, 3, 6, 12 hours.

check box Leads: 3 leads/5 leads (option)

check box Heart rate range: 30 – 300 bpm

check box Heart rate accuracy: approx. 3 bpm

check box ST level: yes

check box PVC Count Display: yes

check box Bandwidth: 0,5 Hz – 40 Hz

check box ECG size (sensitivity): 0,5, 1, 2, 4 mV / cm

check box  Pacemaker detection mode: indicator on waveform display, user selectable

check box  Differential input impedance: >5

check box  CMRR: >90 dB at 50 or 60 Hz

check box  Input dynamic range: approx. 5 mVAC, approx. 300 mVDC

check box  Defibrillator discharge: <5 sec

check box  Arrhytmia analysis: VTAC / VFIB / ASYSTOLIC

check box Lead-off detection: yes

check box ST & PVC analysis: yes

check box Saturation range: 0% – 100%

check box Heart rate: 0 – 254 bpm

check box SpO2 accuracy

70% – 100% = approximately 2%

0% – 69% = unspecified

check box Heart rate accuracy: approx. 2 bpm

check box Pitchtone: yes

check box Method: Oscillometric

check box Operation Mode

Manual: single measurement

Auto automatic intervals of 1, 2, 3, 4, 5, 10, 15, 20, 30 min., and 1, 2, 4, 8 hours

STAT: Continuous measurement during 5 min.

check box Cuff pressure display: 0 – 300 mmHg

check box B.P. measurement range

Systolic: 60 – 250 mmHg

Mean: 40 – 235 mmHg

Diastolic: 30 – 220 mmHg

check box Cuff inflation pressure: adjustable

check box  Range: 5 – 120 breaths / min

check box  Accuracy: approx. 3 breaths / min

check box Measurement range: 15°C – 45°C (59°F – 113°F)

check box Accuracy

25°C – 45°C = 0.1°C

15°C – 24°C = 0.2°C

check box Compatibility: YSI Series 400

check box Standard accessories

3 lead patient cable 1ea 

Electrodes 10 ea

NIBP extension tube (3m) 1 ea

NIBP cuff (25-35cm)

SpO2 sensor extension cable (2m) 1 ea

SpO2 sensor (adult) reusable 1 ea

DC adapter, 18VDC 2.5A 1 ea

check box Optional accessories

Temperature probe: skin, rectal/oral for adults, reusable 5-lead patient cable

NIBP cuff for children and neonates

ECONET

COMPACT 7

check box 10.4″ wide TFT color monitor (800×600 pixels)

check box 7ch. ECG (optional 12ch. ECG), SpO2, NIBP, Respiration, 2xTemperature

check box Various optional EtCO2 modules (mainstream, sidestream)

check box 120 hours trends saving time

check box Networkable with PC (LAN, RS-232, HL7 and optional WLAN)

check box Display: 10.4″ Wide colour TFT-Monitor (800×600)

check box Dimension: 270 (W) x 250 (H) x 184.5 (D)mm, ca. 4.0 kg

check box Indicators

Up to 6 waves (2*ECG, SpO2, RR, or EtCO2, 2*IBP); 

Categorized alarms (4 priority levels);

Visual alarm handle lamp;

Heart rate, SpO2 pitchtone;

Battery status;

External power LED

check box Interfaces

DC input connector: 12 – 18VDC, 2.5A;

Defib. Sync. Output

  • Signal level: 0 – 5 V pulse
  • Pulse width: 100 approx. 10 ms

LAN digital output for transfering data;

Nurse call system connection;

DC output: 5 VDC, 1A max.;

check box Battery

Type: Rechargeable Li-ion battery

Battery status indicator

Operation time: up to 2 hours fully charged

check box Thermal Printer (standard)

Speeds: 25, 50 mm/sec

Paper width: 57 mm

check box Tabular trend: Memory storage: 120 hours

check box EtCO2: Respironics mainstream/sidestream

check box Measurement range: 0 – 150 mmHg

check box Accuracy

0 – 40 mmHg: approx. 2 mmHg

41 – 70 mmHg: approx. 5% of reading

71 – 100 mmHg: approx 8% of reading

101 – 150 mmHg: approx 10% of reading

check box Respiration rate: 2 – 150 breaths per minute

check box Respiration accuracy: Approx 1 breath per minute

check box Leads: 3 leads/5 leads (option)

check box  Lead selection: 

3 leads: I, II, III

5 leads: I, II, III, aVR, aVL, aVF, V

check box  ECG waveforms: 

3 leads: 1 channel

5 leads: 3 – 7 channel

check box Heart rate range: 

Adult: 30 – 300 bpm

Neonate / Pediatric: 30 – 350 bpm

check box Heart rate accuracy: approx. 1 bpm or 1% whichever is greater

check box  Sweep speed: 6.25, 12.5, 25, 50 mm/sec

check box Filter 

Diagnostic mode: 0.05 Hz – 120 Hz

Monitoring mode: 0.5 Hz – 40 Hz

Surgical mode: 0.5 Hz – 25 HZ

check box ST segment detection range: -2.0 to 2.0 mV 

check box Arythmia analysis: asystole, vtach, vfib, bigeminy, accvent, couplet, irregular, pause, pvc, ront, trigeminy, vbrady, shortrun

check box Pacemaker detection mode: indicator on waveform display (user selectable)

check box Protection: against electrosurgical interference and defibrillation

check box Saturation range: 0% – 100%

check box Saturation accuracy: 

70 – 100 = approx. 2 digits

0 – 69 = unspecified

check box Heart rate: 0 – 254 bpm

check box Heart rate accuracy: approx. 2 bpm

check box Method: Oscillometric with linear deflation

check box Operation Mode: manual/automatic or continuous

check box Measurement range

Adult pressure: 20 – 260 mmHg

Pediatric pressure: 20 – 230 mmHg

Neonate pressure: 20 – 120 mmHg

check box Accuracy

Mean error: less than approx. 5 mmHg

Standard deviation: less than 8 mmHg

check box Method: Thoraric impedance

check box Channel selection: RA-LA or RA-LL

check box  Range: 5 – 120 breaths / min

check box  Accuracy: approx. 1breaths / min

check box Apnea alarmyes

check box Measurement range: 15°C – 45°C (59°F – 113°F)

check box Accuracy: approx. 1°C

check box Compatibility: YSI Series 400

check box  Channels: 2

check box Measurement range: -50 to 300 mmHg

check box Accuracy: <100 mmHg, <= 100 mmHg: approx. 1% of reading

check box Pulse rate measurement range: 0 – 300 bpm

check box Zero balancing

Range: approx. 200 mmHg

Accuracy: approx. 1 mmHg

Drift: approx. 1 mmHg over 24 hours

check box Transducer sensitivity: 5qV/mmHg

check box Standard accessories

5 lead patient cable 1ea 

NIBP extension tube 1 ea

NIBP cuff (25-35cm)

SpO2 sensor extension cable (2m) 1 ea

SpO2 sensor (adult) reusable 1 ea

DC adapter, 18VDC 2.5A 1 ea

Thermal paper 2 rolls

check box Optional accessories

Temperature probe: skin, rectal/oral for adults

IBP transducer 

Mainstream/sidestream EtCO2 module

Reusable 3-lead patient cable