ECONET
COMPACT 3
Hoog contrast TFT-scherm met SpO2, NIBP, Temperatuur
Operated through external power supply or vehicle electrical system
Li-ion battery operation for up to 5 hours
Trend memory for over 128 hours
Alarm memory for 20 alarms with 10 sec. each
Integrated connector sockets for Network and USB
Incl. SpO2 sensor blood pressure cuff for adults
Weighs only 1kg
Accessories included
Display: 4,3″ Colour TFT-Monitor
Dimension: 187 (W) x 131 (H) x 60 (D)mm, ca. 1,1 kg
Indicators
Up to 2 waves;
Categorized alarms (4 priority levels);
Heart rate, SpO2 pitchtone;
Battery status;
External power LED
Interfaces
DC input: 15V, 2A;
LAN digital output for transfering data;
Nurse call system connection;
DC output: 5V, 1A max.;
USB Pport;
VGA output (optional)
Battery
Type: rechargeable Li-ion battery
Operation time: up to 5 hours fully charged
Tabular trend
Memory storage: 120 hours
Intervals: 1, 5, 15, 30, 60 min.
Format: tabular form for all parameters
Graphical trend
Display duration: 30, 60, 90, 180, 360, 720 min.
Saturation range: 0% – 100%
Heart rate: 0 – 254 bpm
SpO2 accuracy
70% – 100% = approximately 2%
0% – 69% = unspecified
Heart rate accuracy: approximately 2 bp
Pitchtone: yes
Method: Oscillometric
Operation Mode
Manual: single measurement
Within intervals: 1, 2, 3, 4, 5, 10, 15, 20, 240, 480 min
Measurement range
0 – 300 mmHg
Systole: 60 – 250 mmHg
Mean: 40 – 235 mmHg
Diastole: 30 – 220 mmHg
Cuff pressure: adjustable
Measurement range: 15°C – 45°C (59°F – 113°F)
Accuracy
25°C – 45°C = 0.1°C
15°C – 24°C = 0.2°C
Compatibility: YSI Series 400
Module: Respironics Mainstream/Sidestream
Measurement range: 0 – 150 mmHg
Accuracy
0 – 40 mmHg = 2 %
41 – 70 mmHg = 5%
71 – 100 mmHg = 8%
101 – 150 mmHg = 10%
Respiration rate: 2 – 150 breath per min.
Respiration accuracy: 1 breath per min.
Standard accessories
NIBP extension tube
NIBP cuff (25-35cm)
SpO2 extension cable
SpO2 sensor (adult)
DC adapter, 15V 2A
Optional accessories
Temperature probe: skin, rectal/oral for adults
NIBP cuff for children and neonates
ECONET
COMPACT 5
7″ wide TFT color monitor (800×480 pixels)
2ch. ECG, SpO2, NIBP, Respiration, Temperature
120 hours trends saving time
Networkable with PC (LAN, RS-232, HL7 and optional WLAN)
ST & PVC analysis
Built-in rechargeable Li-ion battery and printer
Display: 7″ Wide colour TFT-Monitor (800×480)
Dimension: 238 (W) x 250 (H) x 155 (D)mm, ca. 3,1 kg
Indicators
Up to 4 waves;
Categorized alarms (3 priority levels);
Heart rate, SpO2 pitchtone;
Battery status;
External power LED
Interfaces
DC input connector: 18VDC, 2.5A;
Defib. Sync. Output
- Signal level: 0 – 5 V pulse
- Pulse width: 100 approx. 10 ms
LAN digital output for transfering data;
Nurse call system connection;
DC output: 3.3 VDC, 1A max.;
Battery
Type: Li-ion battery
Battery status indicator
Operation time: up to 3 hours fully charged
Thermal Printer (standard)
Speeds: 25, 50 mm/sec
Paper width: 57 mm
Tabular trend
Memory storage: 120 hours
Intervals: 1, 5, 15, 30, 60 min.
Format: tabular form for all parameters
Graphical trend
Display duration: 30, 60, 90 minutes, 3, 6, 12 hours.
Leads: 3 leads/5 leads (option)
Heart rate range: 30 – 300 bpm
Heart rate accuracy: approx. 3 bpm
ST level: yes
PVC Count Display: yes
Bandwidth: 0,5 Hz – 40 Hz
ECG size (sensitivity): 0,5, 1, 2, 4 mV / cm
Pacemaker detection mode: indicator on waveform display, user selectable
Differential input impedance: >5
CMRR: >90 dB at 50 or 60 Hz
Input dynamic range: approx. 5 mVAC, approx. 300 mVDC
Defibrillator discharge: <5 sec
Arrhytmia analysis: VTAC / VFIB / ASYSTOLIC
Lead-off detection: yes
ST & PVC analysis: yes
Saturation range: 0% – 100%
Heart rate: 0 – 254 bpm
SpO2 accuracy
70% – 100% = approximately 2%
0% – 69% = unspecified
Heart rate accuracy: approx. 2 bpm
Pitchtone: yes
Method: Oscillometric
Operation Mode
Manual: single measurement
Auto automatic intervals of 1, 2, 3, 4, 5, 10, 15, 20, 30 min., and 1, 2, 4, 8 hours
STAT: Continuous measurement during 5 min.
Cuff pressure display: 0 – 300 mmHg
B.P. measurement range
Systolic: 60 – 250 mmHg
Mean: 40 – 235 mmHg
Diastolic: 30 – 220 mmHg
Cuff inflation pressure: adjustable
Range: 5 – 120 breaths / min
Accuracy: approx. 3 breaths / min
Measurement range: 15°C – 45°C (59°F – 113°F)
Accuracy
25°C – 45°C = 0.1°C
15°C – 24°C = 0.2°C
Compatibility: YSI Series 400
Standard accessories
3 lead patient cable 1ea
Electrodes 10 ea
NIBP extension tube (3m) 1 ea
NIBP cuff (25-35cm)
SpO2 sensor extension cable (2m) 1 ea
SpO2 sensor (adult) reusable 1 ea
DC adapter, 18VDC 2.5A 1 ea
Optional accessories
Temperature probe: skin, rectal/oral for adults, reusable 5-lead patient cable
NIBP cuff for children and neonates
ECONET
COMPACT 7
10.4″ wide TFT color monitor (800×600 pixels)
7ch. ECG (optional 12ch. ECG), SpO2, NIBP, Respiration, 2xTemperature
Various optional EtCO2 modules (mainstream, sidestream)
120 hours trends saving time
Networkable with PC (LAN, RS-232, HL7 and optional WLAN)
Display: 10.4″ Wide colour TFT-Monitor (800×600)
Dimension: 270 (W) x 250 (H) x 184.5 (D)mm, ca. 4.0 kg
Indicators
Up to 6 waves (2*ECG, SpO2, RR, or EtCO2, 2*IBP);
Categorized alarms (4 priority levels);
Visual alarm handle lamp;
Heart rate, SpO2 pitchtone;
Battery status;
External power LED
Interfaces
DC input connector: 12 – 18VDC, 2.5A;
Defib. Sync. Output
- Signal level: 0 – 5 V pulse
- Pulse width: 100 approx. 10 ms
LAN digital output for transfering data;
Nurse call system connection;
DC output: 5 VDC, 1A max.;
Battery
Type: Rechargeable Li-ion battery
Battery status indicator
Operation time: up to 2 hours fully charged
Thermal Printer (standard)
Speeds: 25, 50 mm/sec
Paper width: 57 mm
Tabular trend: Memory storage: 120 hours
EtCO2: Respironics mainstream/sidestream
Measurement range: 0 – 150 mmHg
Accuracy
0 – 40 mmHg: approx. 2 mmHg
41 – 70 mmHg: approx. 5% of reading
71 – 100 mmHg: approx 8% of reading
101 – 150 mmHg: approx 10% of reading
Respiration rate: 2 – 150 breaths per minute
Respiration accuracy: Approx 1 breath per minute
Leads: 3 leads/5 leads (option)
Lead selection:
3 leads: I, II, III
5 leads: I, II, III, aVR, aVL, aVF, V
ECG waveforms:
3 leads: 1 channel
5 leads: 3 – 7 channel
Heart rate range:
Adult: 30 – 300 bpm
Neonate / Pediatric: 30 – 350 bpm
Heart rate accuracy: approx. 1 bpm or 1% whichever is greater
Sweep speed: 6.25, 12.5, 25, 50 mm/sec
Filter
Diagnostic mode: 0.05 Hz – 120 Hz
Monitoring mode: 0.5 Hz – 40 Hz
Surgical mode: 0.5 Hz – 25 HZ
ST segment detection range: -2.0 to 2.0 mV
Arythmia analysis: asystole, vtach, vfib, bigeminy, accvent, couplet, irregular, pause, pvc, ront, trigeminy, vbrady, shortrun
Pacemaker detection mode: indicator on waveform display (user selectable)
Protection: against electrosurgical interference and defibrillation
Saturation range: 0% – 100%
Saturation accuracy:
70 – 100 = approx. 2 digits
0 – 69 = unspecified
Heart rate: 0 – 254 bpm
Heart rate accuracy: approx. 2 bpm
Method: Oscillometric with linear deflation
Operation Mode: manual/automatic or continuous
Measurement range
Adult pressure: 20 – 260 mmHg
Pediatric pressure: 20 – 230 mmHg
Neonate pressure: 20 – 120 mmHg
Accuracy
Mean error: less than approx. 5 mmHg
Standard deviation: less than 8 mmHg
Method: Thoraric impedance
Channel selection: RA-LA or RA-LL
Range: 5 – 120 breaths / min
Accuracy: approx. 1breaths / min
Apnea alarm: yes
Measurement range: 15°C – 45°C (59°F – 113°F)
Accuracy: approx. 1°C
Compatibility: YSI Series 400
Channels: 2
Measurement range: -50 to 300 mmHg
Accuracy: <100 mmHg, <= 100 mmHg: approx. 1% of reading
Pulse rate measurement range: 0 – 300 bpm
Zero balancing
Range: approx. 200 mmHg
Accuracy: approx. 1 mmHg
Drift: approx. 1 mmHg over 24 hours
Transducer sensitivity: 5qV/mmHg
Standard accessories
5 lead patient cable 1ea
NIBP extension tube 1 ea
NIBP cuff (25-35cm)
SpO2 sensor extension cable (2m) 1 ea
SpO2 sensor (adult) reusable 1 ea
DC adapter, 18VDC 2.5A 1 ea
Thermal paper 2 rolls
Optional accessories
Temperature probe: skin, rectal/oral for adults
IBP transducer
Mainstream/sidestream EtCO2 module
Reusable 3-lead patient cable
© 2019, Ecce Medical. All rights reserved.